Product Description

This cable design of Non-Metallic Construction is used, wherever required, from traceability point of view. 

The design is based on stranded loose tube which provides stable performance over a wide temperature range and is compatible with any telecommunications-grade optical fiber.

This Cable has been designed for both Duct and Direct Buried applications. Design strength and rodent protection has been provided by using Polyamide – Nylon and Rodent Resistant Glass Rovings as first (inner) sheath.

The stranded loose tubes contain thixotropic jelly for protection of the optical fibers as required. It is designed on Jelly base, contains the excellent quality filling compound for stopping ingress/transport of water into the cable.

The product is available up to 216 Fibers in both G.652.D and composite construction, it facilitates easy and economical installation.

Features & Application

  • Excellent optical, mechanical & environmental performance
  • High strength-to-weight ratio
  • CSM dielectric type – Fiber Reinforced Plastic
  • Dry block construction
  • High tensile strength
  • High crush strength
  • Corrosion resistance
  • KINK resistance
  • Very light weight
  • Very flexible & small bending radius
  • Long haul / backbone application
  • Junction communication systems
  • All dielectric applications
  • CATV applications

Cable Construction Detail

Construction Parameters

Fiber Count
02 to 288 Fibers
Color of Fiber
As per TIA/EIA-598A
Loose Tube Material
Polybutylene Terephthalate (PBT)
Loose Tube Filling Material
Thixotropic Jelly
Filler Material (if required)
Medium Density/High Density Polyethylene (MDPE/HDPE)
Central Strength Member
Fiber Reinforced Plastic (FRP) – Non Metallic
Core Moisture Protection Methodology
Jelly Filled Construction / Dry Block Construction
Peripheral Strength Member
Glass Yarn
First (Inner) Sheath Material
Nylon
Rodent Protection
Rodent Resistant Glass Rovings
Second (Outer) Sheath Material
High Density Polyethylene (HDPE)
Printing on Outer Sheath
Engraved Hot Foil or Inkjet Printing
Nominal Cable Delivery Length (km)
4 KM ± 3%

Mechanical Characteristics

Tensile Strength (N)
3,000
Crush Strength (N)
2,500
Minimum Bending Radius (mm)
20 x Cable diameter (Full Load)
10 x Cable diameter (No Load)
Temperature Operating Range
-10 to +70°C

Optical Characteristics

Fiber Color Coding
As per TIA/EIA-598A
Fiber Type
Single Mode G.652.D
Mode Field Diameter, µm
8.6 to 9.5 ± 0.7
Cladding Diameter, µm
125 ± 1
Core Clad concentricity error (µm)
≤ 1.0
Clad Non-circulatory %
≤ 2 %
Chromatic Dispersion, ps/ (nm.km)
≤ 3.5 at 1310
≤ 18 at 1550
Polarized Mode Dispersion ps/√km
≤ 0.50
Cut-off Wavelength, nm
≤ 1260
Cabled Attenuation @ 1310 nm (dB/km)
≤ 0.35 (average)
Cabled Attenuation @ 1550 nm (dB/km)
≤ 0.21 (average)

 

 
 

October, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Dubai, UAE.

October, 2012: Premier Cables (Pvt) Limited is participating in Gitex Technology Exhibition to be held in Dubai, United Arab Emirates from October 14-18, 2012.


Read More

September, 2012: Premier Cables (Pvt) Limited participating in ITCN Asia Exhibition 2012

September, 2012: Premier Cables (Pvt) Limited participating in 12th ITCN Asia Exhibition 2012 from 18-20 September, 2012 at Karachi Expo Centre, Pakistan.


Read More

May, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Kingdom of Saudi Arabia.

May, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Kingdom of Saudi Arabia from May 21-24, 2012.


Read More

Premier Cables (Pvt) Limited has been certified with ISO 14001:2004 certification on September 28, 2011

Premier Cables (Pvt) Limited has been certified with ISO 14001:2004 certification on September 28, 2011 in recognition of the organization’s Environmental Management System.


Read More

September, 2011: Premier Cables (Pvt) Limited participated in ITCN Asia Exhibition 2011

September, 2011: Premier Cables (Pvt) Limited participated in ITCN Asia Exhibition 2011, held in Expo Centre Karachi from 20-22 September 2011.


Read More

July, 2011: Premier Cables (Pvt) Limited has been awarded with Brands of the Year Award 2010.
Read More

July, 2011: Premier Cables (Pvt) Limited has been awarded with 8th Annual Environment Excellence Awards for the year 2011.
Read More

May, 2011: Premier Cables (Pvt) Limited participated in Gitex Technology Exhibition held in Kingdom of Saudi Arabia.
Read More

December, 2010: Premier Cables (Pvt) Limited has been awarded with 5th CSR Excellence Award for the year 2010.
Read More

October, 2010: Premier Cables (Pvt) Limited has been awarded with 1st Global CEO Excellence for the Year 2010.
Read More

 
 
 
Premier Cables (Pvt) Limited facilitate customers by Reasonable prices, Best quality cables and wires (100% tested prior to dispatch), Simple process for ordering..
 
 

Mr. M. Ismail Kasim, Matriculate from Baroda Boarding House during the years 1944 to 1947. He passed LLB Examination from S.M. Law College, Karachi. During the year 1964, Mr. Ismail laid the foundation of Premier Cables, he went to Japan …

Read More