Available in 1-2 Fibers (with Standard Single Mode G.652.D Fiber)
Application
Fiber To The Home Technology represent an attractive solution for providing high bandwidth from central office to residences and to small and medium sized businesses. It is cost effective; its simple cable structure provides ease in the network operations.
The cable is designed for Indoor Applications in FTTH configurations with low bending sensitivity fiber; it provides high bandwidth and excellent communication transmission characteristics. Small bending fiber’s fatigue lifetime is several hundred times longer than other standard single mode fibers.
1. Cable Construction
1.1. Cable Design
The optical fibers are placed in the center, Two Parallel Strength Members (Steel Wire or FRP) is placed at the two sides, the cable is then completed with LSZH sheath having a Notch to tear the cable and expose the fibers.
- Fiber: The Cable is based on
- Single Mode Fiber as per ITU-T G.652.D Specs – 9/125
- Also available in ITU-T G.657 – 9/125 Bend Insensitive Fiber
- Fiber Color:
- Any combination (Blue-Orange or Blue-White or as requested)
- Strength Member:
- Fiber Reinforced Plastic or Steel Wire is used as Strength Member.
- Sheaths:
- Sheath of Low Smoke Zero Halogen and Flame Retardant
- Color: White, Ivory, Black or as desired.
- Cable Size:
- 2mm (±0.1mm) x 3mm (±0.1mm)
- Average Cable Weight:
- 9.6kg/km
2. Technical Parameters
| Fiber Count | Size | Tensile Load (N) | Crush Resistance (N) | Impact | Minimum Bending Radius | Repeated Bending | Torsion | Temperature Range | ||
| Short Term | Long Term | Mode | G.652.D | |||||||
| 01 | 2mm x 3mm (±0.1mm) | 150 | 1000 | 300 | 1N-m | Static | 30mm | 300 times
at ± 90° |
20times with
180° Angel |
-20°C to +70°C |
| 02 | 2mm x 3mm (±0.1mm) | 150 | 1000 | 300 | Dynamic | 60mm | ||||
3. Fiber Characteristics
3.1. Geometrical Parameters
| Characteristics | Units | Specified Values |
| G.652.D | ||
| MFD at 1310nm | µm | 8.6 – 9.5 ± 0.6 |
| Cable Cut-off Wavelength | λcc | ≤ 1260nm |
| Cladding Diameter | µm | 125 ± 1 |
| Core Clad Concentricity | µm | ≤ 0.5 |
| Cladding Non-circularity | % | ≤ 12 |
| Coating Diameter | µm | 245 ± 10 |
3.2. Optical Characteristics
| Characteristics | Units | Specified Values |
| G.652.D | ||
| Attenuation at 1310nm | dB/Km | ≤ 0.4 |
| Attenuation at 1550nm | dB/Km | ≤ 0.3 |
| Zero Dispersion Wavelength | nm | 1300 – 1322 |
| Zero Dispersion Slope | ps/nm².km | ≤ 0.092 |
| Chromatic Dispersion at 1310nm | ps/nm.km | ≤ 3.5 |
| Chromatic Dispersion at 1550nm | ps/√km | ≤ 18 |
| PMD | ps/√km | ≤ 0.2 |
3.3 Mechanical Parameters
| Characteristics | Units | Specified Values |
| G.652.D | ||
| Proof Test | % | ≥ 1 |
| Temperature Cycling | °C | -20 to +70 |
| Humidity | 85% R.H. | ≤ 0.05dB/Km |
| Storage / Operating Temperature | °C | -20 to +70 |
4. Physical / Mechanical / Environmental Performance and Tests
| Characteristics | Test Method |
| Tensile Loading & Bending | IEC 60794-1-2-E1 |
| Compression | IEC 60794-1-2-E3 |
| Impact | IEC 60794-1-2-E4 |
| Cable Bending / Torsion | IEC 60794-1-2-E6 / E7 |
| Temperature Cycling | IEC 60794-1-2-F1 |
| Cable Bend at High and Low Temperature | IEC 60794-1-2-E11 |
5. Handling : Points to be taken care-off
- Cable not to be installed below Minimum Bending Radius
- Cable not to be pulled beyond maximum pulling tension
- Sharp directional changes be avoided
- Unwinding of the cable to be made as per indication on the drum
- In vertical installations, it should be from Top to Bottom
6. Marking & Packing
- Cable Marking
- The cable shall be marked at every meter
- Standard Length
- Standard length of cable shall be 1Km or 2Km or as required.
- Packing
- Each cable drum shall be packed in a wooden drum to protect the cable during normal handling and shipping.