For Quality You Can Trust
Since 1964

Jelly Filled Copper Cable (Armoured)

Product Description

Polythene insulated jelly filled, armored Telecommunication Cables (10 to 200 pairs with conductors’ dia of 0.4mm, 0.5mm, 0.6mm and 0.9mm) are manufactured on Pakistan Telecommunication Company specifications LW-33P with reference to various international standards and specifications. Premier Cables offers a wide range of Telephone cables.

Application

This cable is usually used for direct buried applications for distribution in the exchange areas as local network and interexchange applications. It is a cable with solid polyethylene insulated unit twin jelly filled construction.

Cable Construction Detail

Construction

  1. Conductor: Solid annealed copperith conductor sizes of 0.4 & 0.6mm.
  2. Insulation: Colored high molecular weight solid High Density Polyethylene.
  3. Color Coding: Cables are fully color coded in accordance with PIC even count color code.
  4. Twining/pairing: Two colored insulated conductors are uniformly twisted together to form a pair. Varying lay length is designed to minimize the cross talk and capacitance unbalance.
  5. Stranding / Cabling: Twisted pairs are assembled into unit of 25 pairs. When desired for lay-up reason, the units are divided into two or more sub-units, which are bind with durably colored polyethylene tapes to form a compact and circular cable.
  6. Filling Compound: The water resistant filling compound is applied to the air space within the cable core.
  7. Core Covering: A non-hygroscopic and dielectric Polyester Tape and Water Blocking Tape are applied helically having a suitable overlap.
  8. Flooding Compound: Sufficient flooding compound is applied between the core wrap and shield.
  9. Moisture Barrier Inner Sheath: An aluminum tape with co-polymer coating is applied over the cable core and then sheathed with black polyethylene compound.
  10. Jacket: Black High Molecular weight low density polyethylene compound.
  11. Identification: A plastic tape, duly marked with the manufacturers name, year of manufacture and cable size, if required, is placed under the core covering. Alternatively, thesse details may be printed on the outer jacket of cable.

Physical and Electrical Tests

Parameters Conductor Size (mm)
0.4
0.5
0.6
0.9
Conductor Resistance
(per K.M in Ohms) individual
145
92
63
30
Conductor Resistance unbalance
Individual
5 %
5 %
5 %
5 %
Average
1.5 %
1.5 %
1.5 %
1.5 %
Conductor Elongation (Minimum percent)
15 %
15 %
15 %
15 %
Tensile Strength
200 MPa
200 MPa
200 MPa
200 MPa
Attenuation at 150 Khz (dB/km) shall not exceed
11.2
8.4
6.8
8.4
Insulation
Solid (MDPE/HDPE)
Tensile Strength
16.5 MPa
16.5 MPa
16.5 MPa
16.5 MPa
Ultimate Elongation
350%
350%
350%
350%
Spark Test
2.5KV RMS AC for 3 seconds (PP), 10KV RMS AC for 3 seconds (PS)
Retraction of Insulation(shall not exceed)
2.5mm after 1 min.
Resistance to Compression
200N, 12 Volt DC
Insulation Resistance at 500V
5000 Mega Ohm / Km
Construction
25 Pair Unit
Filling Compound
Water Resistant Compound (Petro Jelly)
Core wrap
Polyester Tape
Moisture Barrier
Poly-Aluminum
Sheath / Jacket
HDPE
Armoring
Galvanized Steel Tape
Armoring Bedding
PE Tape
Mutual Capacitance (nF/KM)
Individual
52 ± 4
Average
52 ± 3
Capacitance Unbalance (pF/KM)pair to pair
Individual
333
Average
S83.3o
Cross Talk
RMS average -73.0 dB
Shield Resistance
62.5 Ohm per Drum
 
 

October, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Dubai, UAE.

October, 2012: Premier Cables (Pvt) Limited is participating in Gitex Technology Exhibition to be held in Dubai, United Arab Emirates from October 14-18, 2012.


Read More

September, 2012: Premier Cables (Pvt) Limited participating in ITCN Asia Exhibition 2012

September, 2012: Premier Cables (Pvt) Limited participating in 12th ITCN Asia Exhibition 2012 from 18-20 September, 2012 at Karachi Expo Centre, Pakistan.


Read More

May, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Kingdom of Saudi Arabia.

May, 2012: Premier Cables (Pvt) Limited participating in Gitex Technology Exhibition to be held in Kingdom of Saudi Arabia from May 21-24, 2012.


Read More

Premier Cables (Pvt) Limited has been certified with ISO 14001:2004 certification on September 28, 2011

Premier Cables (Pvt) Limited has been certified with ISO 14001:2004 certification on September 28, 2011 in recognition of the organization’s Environmental Management System.


Read More

September, 2011: Premier Cables (Pvt) Limited participated in ITCN Asia Exhibition 2011

September, 2011: Premier Cables (Pvt) Limited participated in ITCN Asia Exhibition 2011, held in Expo Centre Karachi from 20-22 September 2011.


Read More

July, 2011: Premier Cables (Pvt) Limited has been awarded with Brands of the Year Award 2010.
Read More

July, 2011: Premier Cables (Pvt) Limited has been awarded with 8th Annual Environment Excellence Awards for the year 2011.
Read More

May, 2011: Premier Cables (Pvt) Limited participated in Gitex Technology Exhibition held in Kingdom of Saudi Arabia.
Read More

December, 2010: Premier Cables (Pvt) Limited has been awarded with 5th CSR Excellence Award for the year 2010.
Read More

October, 2010: Premier Cables (Pvt) Limited has been awarded with 1st Global CEO Excellence for the Year 2010.
Read More

 
 
 
Premier Cables (Pvt) Limited facilitate customers by Reasonable prices, Best quality cables and wires (100% tested prior to dispatch), Simple process for ordering..
 
 

Mr. M. Ismail Kasim, Matriculate from Baroda Boarding House during the years 1944 to 1947. He passed LLB Examination from S.M. Law College, Karachi. During the year 1964, Mr. Ismail laid the foundation of Premier Cables, he went to Japan …

Read More